Probably Stolen Contaminated Product: Causes and Fixes

Why a Probably Stolen chemistry batch is contaminated: Chem Finisher penalty, dirty acid and water, temperature errors, and the module fixes that raise purity.

Last Updated: 2026-11-11

A contaminated batch in Probably Stolen is not a random failure. The game adds contamination at specific points, and most bad batches trace back to one of four causes: an unmodded Chem Finisher, dirty acid or base, impure water, or a temperature setting that cooked the product.

The frustrating part is that the game labels the result by purity tier, not by cause. A 78% batch and an 88% batch can both look "contaminated" in the price window while having completely different fixes.

This page walks the causes in the order you should check them.

Chemistry equipment and a finished batch in Probably Stolen
Chemistry equipment and a finished batch in Probably Stolen

What "contaminated" means in the purity system

Purity is bucketed, and each bucket changes the sale price:

Purity Tier Price modifier
99%+ Lab Pure +135%
90–99% Pharma +85%
80–90% Near-Pharma +40%
60–80% Street Standard 0%
45–60% Cut −45%
30–45% Junk −75%
Under 30% Starch −95%

The jump from 89% to 90% is worth 45 percentage points of price. That is why players search for a contamination fix: the last few points are the most expensive to lose.

Contamination is one input to that number. Temperature failures and bad reagents can also wreck a batch without the word "contamination" appearing anywhere.

Cause 1: the Chem Finisher's base penalty

The Chem Finisher adds contamination every time it finishes a batch. The base penalty is 12%. Modules reduce it:

Finisher modules Contamination added
0 12%
1 6%
2 3%
3 1%
4 0%

This is the single biggest lever. With no modules, a perfectly clean input still gets 12% added at the finisher. With three modules, a clean batch can just reach 99%; with four, you have margin.

If your product consistently lands in Street Standard or Near-Pharma, count your finisher modules before you blame the recipe. A Quality module elsewhere does not replace a finisher module.

Cause 2: contaminated acid or base

Acid and base contain heavy metals, and heavy metals cannot be removed by filtering or purification tablets. If the input is contaminated, the output is contaminated. There is no downstream fix.

The Composition Spectrometer is the tool that shows which supplier batch is cleanest. Buy the cleanest acid or base you can afford, and test before committing a full batch. Two bottles with the same label are not guaranteed to have the same contaminant profile.

This is the most common reason a chemistry run stalls after the player has already solved the finisher problem. The chemical supplies guide→ covers supplier batches and testing.

Cause 3: impure water

Water is not a neutral filler. Its purity and contaminant profile affect the batch. Use the cleanest water you can afford, and do not use a bottle you have not tested.

A purification tablet only works in a container that already has water. It is not a cleaner for an empty machine, and it is not a substitute for clean input. The water guide→ covers grades and purification.

The 1.0.0.12 update changed a stock Water Purifier to clean water to 99.01% instead of 99.00%. That is a small buff, not a guarantee; the purifier still has to be running and supplied.

Cause 4: temperature damage

Temperature errors do not always show as "contamination", but they destroy batches in ways players describe the same way. The documented failure points:

Product Failure threshold
Dream Cap extract Denatures above 60°C
Nightmare extract Above 50°C
Alcohol Evaporates above 78°C
Lipobond Evaporates above 55°C

A stock Heating Plate is fixed at 99°C. It cannot make a recipe that needs 40–49°C without destroying it. One module raises the cap to 160°C; two modules allow custom temperature selection.

The in-game Chemistry 101 text and community testing disagree on the Dream Cap window: the manual says 40–60°C, while testers report anything above 50°C turns it into plant matter. Use 40–49°C and verify on your build.

Diagnosis order

When a batch comes out bad, check in this order:

  1. Finisher modules. Count them. Zero modules means +12% contamination before anything else.
  2. Acid and base. Test with the Composition Spectrometer. Heavy metals cannot be filtered out.
  3. Water. Test the bottle. A clean-looking water grade can still carry contaminants.
  4. Temperature. Compare the recipe card to the plate's actual setting and the product's failure threshold.
  5. Recipe. Confirm you used the right inputs and the right finishing step.

Do not start by buying a more expensive recipe. The chemistry recipes→ page lists temperatures and yields; the failure is usually upstream of the recipe.

Can you clean a contaminated finished batch?

There is no documented purification step for a finished product in the sources used here. A purification tablet works on water in a container, not on a completed batch. If the batch is already contaminated, the practical options are to sell it at the tier it lands in or accept the loss.

That is why prevention is the whole game. A 12% finisher penalty is predictable; a contaminated acid bottle is not.

Prevention checklist

  • Install at least one Finisher module before running a product you care about.
  • Test every acid and base bottle with the Composition Spectrometer.
  • Use the cleanest water you can afford, and test it.
  • Match the Heating Plate to the recipe before starting.
  • Keep a reserve for a failed batch; do not spend the rent money on rare reagents.
  • Record the purity of each successful batch so you can repeat it.
One variable at a time

Change one input or one module between batches. If you change the water, the acid and the temperature at once, you learn nothing from a good result.

When to upgrade instead of troubleshoot

If your inputs are clean, your water is tested and your temperature is right, the remaining fix is finisher modules. Two modules bring contamination to 3%; three bring it to 1%; four bring it to 0%. That is the difference between Near-Pharma and Lab Pure on a clean batch.

The chemistry guide→ covers the full machine chain and module math. The module list→ has the confirmed values.

FAQ

Why is my Probably Stolen product contaminated?

The Chem Finisher adds a base 12% contamination. Contaminated acid, base or water can add more, and a temperature failure can ruin the batch independently.

How do I reduce contamination?

Install Chem Finisher modules. The penalty drops from 12% at zero modules to 6%, 3%, 1% and 0% at one through four modules.

Can I filter heavy metals out of acid?

No. Heavy metals cannot be removed by filtering or purification tablets. Test the supplier batch with the Composition Spectrometer and buy clean input.

Does water purity matter?

Yes. Water's purity and contaminant profile affect the batch. Test it and use the cleanest water you can afford.

Can I fix a contaminated batch after it is finished?

There is no documented cleaning step for a finished product. Sell it at its tier or accept the loss, and fix the cause before the next run.

Sources

Contamination values, purity tiers and temperature thresholds come from the in-game chemistry manual and community testing recorded on the site's chemistry pages. The water purifier change is documented in the official 1.0.0.12 update notes. The Dream Cap disagreement is labeled in the chemistry guide.